In industries that need chillers to operate in a dangerous environment, explosion-proof chillers are the best solution. Petrochemical plants and laboratories are a couple of places that use these hard-working, rugged cooling units. But those are not the only industries that benefit from the added safety of an explosion-proof chilling unit. Because explosion-proof chiller manufacturers design these units to specifications based on the environment you install them in, knowing as much as you can about these chillers can aid in determining if one of these units is right for your situation.
ایک دھماکہ پروف چلر کیا ہے؟
دھماکہ پروف چلرز چیلر کے اجزاء کو محیط آتش گیر مادوں سے بچانے کے لیے ایک مضبوط ڈیزائن ہے جو دھماکے کا سبب بن سکتا ہے۔ تجارتی استعمال کے لیے خریداری کے لیے دستیاب کوئی معیاری چلر دھماکہ پروف کے طور پر اہل نہیں ہیں۔ کمپنی کو دہن سے بچانے کے لیے مخصوص ضوابط پر عمل کرنے کے لیے چلر بنانا چاہیے۔
The machinery must have sealed wiring to protect the air from stray sparks that could ignite any vapors or flammable gases. Adhering to these guidelines and fulfilling our customers’ needs require us to custom-design many of our explosion-proof chillers.
دھماکہ پروف چلرز اتنے اہم کیوں ہیں۔
ملازمین اور سہولت دونوں کی حفاظت کے لیے، دھماکے کے امکانات کو کم کرنا کسی بھی کاروباری مالک کے لیے بنیادی مقصد بن جاتا ہے۔ کچھ کام کی جگہیں دوسروں کے مقابلے میں زیادہ خطرے کا شکار ہوتی ہیں۔ اس خطرے کو کم کرنا کہ چلر سے نکلنے والی چنگاری دھماکہ خیز یا آتش گیر مواد کو بھڑکا سکتی ہے اسی لیے دھماکہ پروف چلرز بہت سی صنعتوں کے لیے حفاظتی تقاضے ہیں۔ اگرچہ تمام دھماکہ پروف آلات ایک پریمیم قیمت پر آتے ہیں، لیکن یہ قیمت غلط مشینری کے استعمال کی وجہ سے صنعتی حادثے میں ہونے والی جانی نقصان سے بہت کم ہے۔
حفاظتی مسئلہ ہونے کے علاوہ، قانون کے مطابق کئی مقامات پر جن میں ہوا میں آتش گیر مواد موجود ہوتا ہے، دھماکہ پروف چلرز کی ضرورت ہوتی ہے۔ تعمیل کرنے میں ناکامی کے نتیجے میں آتش گیر مواد کو بھڑکانے کے خطرے کے علاوہ بھاری جرمانے بھی لگ سکتے ہیں۔
ایک دھماکہ پروف چلر کیسے کام کرتا ہے؟
ایک سے زیادہ اقسام کے دھماکہ پروف چلرز دستیاب ہیں، ہر ایک کیسے کام کرتا ہے اس کا انحصار استعمال شدہ اجزاء پر ہوتا ہے۔ مثال کے طور پر، دونوں ہیں پیچ اور سکرول کمپریسرز and air-cooled and water-cooled condensers. The parts of a chiller system don’t make it explosion-proof. The design of the overall system does. However, the components determine the final efficiency of the chiller and the temperatures it can reach. Use this information when selecting a chiller for your worksites.
زیادہ تر چلرز اسی طرح کام کرتے ہیں، مختصراً، چِلرز مطلوبہ درجہ حرارت پر بخارات کے ٹھنڈے حصے میں فریج کے مسلسل بہاؤ کو پہنچا کر کام کرتے ہیں۔ اس کے بعد ایک چلر آپ کے آلات سے گرمی کو ہٹانے اور اسے واپسی کی طرف واپس کرنے کے لیے ٹھنڈے ہوئے سیال کو پمپ کرتا ہے۔ ہمارے چِلرز کے انتخاب میں ایک ہے۔ -60 ڈگری فارن ہائیٹ سے 30 ڈگری فارن ہائیٹ کی حد. Ask us if you have any specific requirements for the cooling from your chiller unit.
Refrigerant starts the process in a mixture of liquid and gas. The gas and liquid move into the evaporator, where heat transforms the refrigerant into a gas with low pressure. This gas moves into the compressor, which uses one of several methods to compress the gas into a high-pressure state. This gas moves to the condenser, which may use water or air to cool the refrigerant. In the condenser, the coolant gives off its heat and condenses back into a liquid. This liquid is at high pressure when it passes through an expansion valve that controls how much of the cooled refrigerant passes into the evaporator to begin the cycle anew.
دھماکہ پروف چلرز کی اقسام
آپ کئی قسم کے دھماکہ پروف چلرز میں سے انتخاب کر سکتے ہیں، بشمول:
- اسکرول چلرز: اسکرول کمپریسرز کے ساتھ چلر یونٹس کے کمپریسرز میں انٹر لاکنگ سرپل ہوتے ہیں۔ جیسے ہی گرم، کم دباؤ والا ریفریجرینٹ ان سے گزرتا ہے، اسکرول ریفریجرینٹ کا دباؤ بڑھاتے ہیں، جب تک کہ یہ مطلوبہ ہائی پریشر، گرم حالت میں باہر نہ نکل جائے۔
- سکرو چلرز: ایک سکرو چلر میں کمپریسر ریفریجرینٹ کو ہائی پریشر والی حالت میں دبانے کے لیے ایک یا دو پیچ استعمال کرتا ہے۔
- ہوا سے چلنے والے چیلرز: یہ ایئر کولڈ چلرز ہائی پریشر، گرم ریفریجرینٹ کو کنڈینسر کے ذریعے سے گزرتے ہیں جو ٹیوبوں کے اندر ہوا اڑاتا ہے۔ یہ ہوا کو ٹھنڈا کرنے کا عمل اس طرح ہے جس طرح ایک کار ریڈی ایٹر انجن کولنٹ سے گرمی کو ہٹاتا ہے۔ ہوا ریفریجرینٹ سے گرمی کو ہٹانے کے بعد، یہ بخارات کو منتقل کرتی ہے۔
- پانی سے ٹھنڈا ہوا مرچ: Water removes heat from refrigerants in water-cooled condensers. Cold water passes into the condenser, where it absorbs heat from the refrigerant. After heating, it flows out of the condenser, and the cooled refrigerant moves on to the evaporator.
What sets explosion-proof cooling units apart from standard units is the protection of the components. Wires move through sealed conduits and motors have air-tight junction boxes. Seals further prevent flammable gas from entering the system. By completely sealing the electrical components, chiller manufacturers allow these units to be installed even in dangerous places.
Understanding Explosion-Proof Classes
Explosion-proof classifications, devised by the National Electric Code (NEC), are pivotal safety standards aimed at minimizing the risk of explosions in environments harboring flammable gases, vapors, or combustible materials. These guidelines play a vital role in categorizing electrical gadgets and equipment based on their resilience to contain potential explosions within their structures.
Adherence to these classifications is critical in industries such as oil and gas, chemical processing, mining, and manufacturing. Following these guidelines not only safeguards personnel and assets but also significantly diminishes the likelihood of catastrophic events, thereby maintaining a high standard of operational integrity in high-risk settings.
قسم | Sub-category | Definition |
---|---|---|
Class | Class I | For hazardous locations containing flammable gases or vapors. |
Class II | For hazardous locations with combustible dust. | |
Class III | For hazardous locations where ignitable fibers or flyings are present. | |
Division | Division I | Designates locations where explosive materials are present under normal operating conditions. |
Division II | Designates locations where explosive materials are handled or stored but are confined and controlled. | |
Group (Class I) | Group A | Atmospheres containing acetylene. |
Group B | Locations containing hydrogen, or gases of equivalent hazard, such as manufactured gas. | |
Group C | Locations containing ethyl-ether vapors, ethylene, or cyclopropane. | |
Group D | Locations containing gasoline, naphtha, hexane, benzine, butane, benzol, acetone, alcohol, lacquer solvent vapors, or natural gas. | |
Group (Class II) | Group E | Locations containing metal dust, including aluminum, magnesium, and their commercial alloys and other similarly hazardous metals. |
Group F | Locations containing coal, carbon black, or coke dust. | |
Group G | Locations containing starch, flour, or grain dust. |
دھماکہ پروف چلر ایپلی کیشنز
دھماکہ پروف چلرز صرف فیکٹریوں میں استعمال کے لیے نہیں ہیں۔ خطرناک ماحول کے لیے بنائے گئے کولنگ یونٹس میں کئی ایپلی کیشنز ہوتے ہیں۔ کچھ کمپنیاں جنہیں اکثر خاص طور پر مہر بند چلرز کی ضرورت ہوتی ہے ان میں شامل ہیں:
- ریفائنریز: Petrochemical refinement requires extreme caution with all materials used. Refineries produce the flammable vapors that require Class 1 explosion-proof chillers.
- نمونہ یا عمل تجزیہ کار: نمونے یا عمل کے تجزیہ کاروں کے ساتھ، کارکن مختلف مادوں کے کیمیائی میک اپ کی شناخت کرتے ہیں۔ چونکہ مواد میں نامعلوم مرکبات ہیں اور اس میں خطرناک مواد شامل ہو سکتا ہے، اس لیے نمونے کے تجزیہ کرنے والے علاقوں میں دھماکے سے تحفظ زندگیاں بچا سکتا ہے۔
- غلہ جات: آٹا انتہائی آتش گیر ہے۔ کسی سے پوچھیں جو اناج سائلو کے قریب رہا ہو اور اس نے دھماکوں کے بارے میں کہانیاں سنی ہوں۔ ہوا میں موجود باریک دھول کو اسے بجھانے کے لیے صرف ایک چھوٹی چنگاری کی ضرورت ہوتی ہے۔ اس لیے سائلوز اور گرانریز کو دھماکہ پروف آلات کی ضرورت ہوتی ہے۔
- لیبارٹریز: Ventilation in labs is critical to the safety and health of the workers. Fire safety and explosion-proofing where needed are also important. Anywhere volatile, flammable vapors or gases exist, you need particular electric parts to resist creating stray sparks that could ignite.
- کیمیائی پودے: کیمیائی پودے ممکنہ طور پر آتش گیر مادے پیدا یا ذخیرہ کر سکتے ہیں۔ یہاں تک کہ سٹوریج کی جگہوں میں، سہولت کو دھماکہ پروف آلات کی ضرورت ہوگی۔ ہم سے ہمارے کیمیائی پلانٹ کے حل یا ہمارے کچھ پچھلے کیمیکل صارفین کے بارے میں پوچھیں۔
- پیٹرو کیمیکل پلانٹس: پیٹرو کیمیکل پلانٹ کو ریفائنری سے ممتاز کرنے کے لیے، سابقہ پیٹرولیم سے مادے بناتا ہے جب کہ مؤخر الذکر خام تیل کو صاف کرتا ہے۔ دونوں ہی خطرناک مواد کو سنبھالتے ہیں۔ جس چیز کا ایک حصہ بہت سے پیٹرو کیمیکلز، جیسے کہ پٹرول، کو مطلوبہ بناتا ہے ان کی آتش گیریت ہے۔ یہی خاصیت پیٹرو کیمیکل پلانٹس کو بھی آگ کے خطرے میں ڈالتی ہے۔
- آتش گیر مائعات کو ٹھنڈا کرنا: آتش گیر مائعات اکثر خطرناک بخارات چھوڑ دیتے ہیں۔ یہ بخارات ضروری جگہ میں دھماکہ پروف چلرز اور دیگر سامان بناتے ہیں۔ اگر سیال بند رہتے ہیں، تو علاقے کو صرف کلاس I، ڈویژن 2 سے منظور شدہ یونٹس کی ضرورت ہوگی۔
چلر کا فیصلہ کرنا
آپ جانتے ہیں کہ آپ کو ایک دھماکہ پروف چلر کی ضرورت ہے، لیکن آپ کو متعدد اختیارات میں سے انتخاب کرنے کی ضرورت ہوگی۔ سب سے پہلے، آپ کو چلر کا سائز جاننے کی ضرورت ہوگی، حالانکہ یہ صرف طول و عرض کا حوالہ نہیں دیتا ہے۔ ٹھنڈک کی صلاحیت کو محتاط حساب کی ضرورت ہوتی ہے تاکہ یہ یقینی بنایا جا سکے کہ آپ پیسہ ضائع نہیں کرتے ہیں یا ایک غیر موثر چلر کا انتخاب نہیں کرتے ہیں۔ مزید برآں، آپ کو یہ جاننے کی ضرورت ہوگی کہ NEC وضاحتوں کی بنیاد پر چلر روم کس زمرے میں آتا ہے۔ آپ جس سے بھی خریدتے ہیں، یقینی بنائیں اور اپنی تحقیق کریں۔ تمام "دھماکا پروف" چلرز ایک جیسے نہیں بنائے جاتے ہیں۔
ایک دھماکہ پروف چلر کا سائز بنانا
چلرز مختلف قسم کے کولنگ کی صلاحیتوں میں آتے ہیں۔ چلر کی قسم کے لحاظ سے ہماری رینج 1 سے 1000 ٹن تک ہوتی ہے۔ چلر کا صحیح سائز معلوم کرنے کے لیے، آپ کو درجہ حرارت میں کمی اور بہاؤ کی شرح جاننے کی ضرورت ہے۔ چلر میں سیال کا درجہ حرارت مائنس ٹھنڈا سیال درجہ حرارت، فارن ہائیٹ میں ماپا جاتا ہے، درجہ حرارت میں کمی کی ضرورت ہے۔ آپ ہمارا حوالہ دے سکتے ہیں۔ چیلر کیلکولیٹر.
Ideally, you don’t want to select a chiller that is too small. Your system will constantly work and never shut off to attain a temperature it cannot reach. This overtaxes the system, shortening its life and increasing the need for repairs. Conversely, don’t oversize a unit too much. If you purchase a unit that is too large for your needs, you may have trouble fitting it into your space and pay too much for cooling you’ll never use. Size becomes an especially critical issue with explosion-proof chillers, which we often custom-build. Know your ideal cooling capacity when ordering to make the process faster.