When it comes to cooling large buildings or industrial processes, absorption chillers offer a unique twist on refrigeration. Unlike conventional systems that rely on electric compressors, these chillers use heat—often from waste sources or natural gas—to drive the cooling process. This makes them a standout choice for energy-conscious facilities. Whether you’re an engineer, a facility manager, or simply intrigued by innovative HVAC tech, this article unpacks how absorption chillers work, their key components, and why they’re a game-changer in specific scenarios.

What Is an Absorption Chiller?

Enfriador de absorción

Un enfriador de absorción es un sistema de refrigeración que aprovecha la energía térmica para producir agua fría, que luego se usa para enfriar el aire o los procesos. En lugar de comprimir mecánicamente un refrigerante con un compresor impulsado por el motor, emplea un proceso químico llamado absorción, utilizando un par de fluidos, típicamente agua y bromuro de litio (LIB), para transferir calor. Este enfoque basado en el calor lo distingue de los enfriadores de compresión de vapor, lo que lo hace ideal para sitios con abundantes fuentes de calor o la necesidad de reducir los costos de electricidad.

La magia radica en su capacidad para convertir el calor residual (piense en vapor de una planta de energía o agua caliente de una matriz solar, en un enfriamiento útil. Común en aplicaciones a gran escala como hospitales, universidades o plantas químicas, los enfriadores de absorción varían de 10 toneladas a más de 1,500 toneladas de capacidad de enfriamiento, ofreciendo un giro sostenible sobre el control climático.

How Does an Absorption Chiller Work?

El ciclo de absorción imita el ciclo de compresión de vapor pero intercambia la potencia mecánica de la energía térmica. Aquí hay una mirada paso a paso al proceso, utilizando un sistema de bromuro de litio de agua como ejemplo:

  1. Evaporación: El ciclo comienza en el evaporador, donde el agua líquida (el refrigerante) se rocía sobre un paquete de tubo que transporta agua de retorno tibia (por ejemplo, 54 ° F o 12 ° C). Bajo un vacío profundo, alrededor de 0.12 psi (0.008 bar), el agua se evapora a baja temperatura (alrededor de 40 ° F o 4 ° C), absorbiendo el calor de los tubos. Esto enfría el agua dentro de, digamos, 44 ° F (7 ° C), que luego se bombea para enfriar un edificio.
  2. Absorción: El vapor de agua producido por las derivaciones en el absorbedor, donde cumple con una solución concentrada de bromuro de litio. Libr, un poderoso absorbente, absorbe el vapor, convirtiéndolo nuevamente en un líquido y liberando calor en el proceso. Esta solución diluida se mantiene al vacío para mejorar la eficiencia de absorción.
  3. Generación: The now-diluted LiBr solution is pumped to the generator, where heat—typically from steam, hot water (above 190°F or 88°C), or a gas burner—boils off the absorbed water. This concentrates the LiBr again, while the water vapor rises to the next stage. The heat source is the engine here, driving the cycle without electricity.
  4. Condensación: The water vapor enters the condenser, where it releases its heat to a cooling medium (usually water from a cooling tower at 85°F or 29°C). As it cools, it condenses back into a liquid, ready to return to the evaporator.
  5. Cycle Repeat: El agua líquida fluye de regreso al evaporador a través de una válvula del acelerador, bajando su presión, mientras que el libr concentrado regresa al absorbedor, manteniendo vivo el bucle.

Este baile de calor y química produce agua fría con piezas móviles mínimas, dependiendo de las bombas en lugar de los compresores para el movimiento de fluidos. Un enfriador de efecto único utiliza una etapa de calor, mientras que los modelos de doble efecto agregan un segundo generador para una mayor eficiencia, a menudo duplicando la salida de enfriamiento por unidad de entrada de calor.

Key Components of an Absorption Chiller

sistema-de-absorción-de-vapor

Cada parte está diseñada para precisión:

  • Evaporador: Una cámara de vacío donde se evapora el agua, enfriando el agua circulante. A menudo, un diseño de carcasa y tubo para la máxima transferencia de calor.
  • Amortiguador: Mixes vapor with the absorbent (LiBr), typically a spray system or packed bed to boost contact area.
  • Generator: The heat-driven heart, separating refrigerant from absorbent. Steam at 15 psi (1 bar) or hot water at 240°F (115°C) is common.
  • Condensador: Cools and condenses the vapor, usually paired with a cooling tower for heat rejection.
  • Intercambiador de calor: Preheats the dilute solution heading to the generator with hot concentrated solution returning to the absorber, slashing energy waste.
  • Pumps and Valves: Move fluids and maintain vacuum—small but critical for flow control.

Some units use ammonia as a refrigerant with water as the absorbent, reversing the pairing for low-temperature applications like -20°F (-29°C) freezing.

Why Use Absorption Chillers?

Absorption chillers shine in specific contexts:

  • Heat Utilization: They turn waste heat—say, from a cogeneration plant producing 300°F (149°C) exhaust—into cooling, slashing electric demand. A hospital might save 50% on cooling costs this way.
  • Low Electricity Use: With pumps drawing just 5-10% of a compressor’s power, they’re perfect where electricity is pricey or unreliable.
  • Quiet Operation: No roaring compressor means noise levels hover around 60 dBA—library-quiet compared to 80+ dBA for vapor compression units.
  • Respetuoso del medio ambiente: Water-LiBr systems have zero ozone depletion potential (ODP), and ammonia options boast a GWP of 0, aligning with green goals.

Aplicaciones

  • District Cooling: Un campus universitario puede usar un enfriador de absorción de 1,000 toneladas, alimentado por vapor desde una planta de energía cercana, hasta dormitorios y laboratorios.
  • Procesos Industriales: Una reacción exotérmica de enfriamiento de la planta química a 50 ° F (10 ° C) podría aprovechar el calor de los reactores, aumentando la eficiencia.
  • Almacenamiento de alimentos: Los enfriadores de agua amoníaco congelan a los peces a -40 ° F (-40 ° C) en almacenes costeros, aprovechando los quemadores de gas donde la electricidad es escasa.

Imagen una cervecería: los tanques de fermentación necesitan enfriamiento constante de 55 ° F (13 ° C). Un enfriador de absorción, alimentado por agua caliente de una caldera de biomasa, mantiene perfecta la cerveza mientras corta la dependencia de la red.

Benefits in Detail

  • Eficiencia energética: Los enfriadores de doble efecto alcanzaron un coeficiente de rendimiento (COP) de 1.2, produciendo 1.2 unidades de enfriamiento por unidad de calor, versus 0.7 para modelos de efectos individuales.
  • Ahorro de costos: En áreas con calor barato (por ejemplo, $ 5/mmbtu de gas frente a electricidad de $ 0.15/kWh), los costos operativos caen 30-40%.
  • Longevidad: Con menos piezas móviles, las unidades a menudo duran 25 años, superando los sistemas basados ​​en el compresor propensos a usar.

Final Words

Los enfriadores de absorción convierten el calor en frío con un giro inteligente, ofreciendo una opción sostenible de baja electricidad para el enfriamiento a gran escala. Desde recortar costos en plantas ricas en calor hasta campus en silencio, son una herramienta nicho pero poderosa. Ya sea que esté adaptando una instalación o explorando la tecnología verde, la comprensión de los enfriadores de absorción puede desbloquear soluciones más inteligentes. ¿Tienes curiosidad por aprovechar esta magia basada en el calor? ¡Alcanza a un especialista en HVAC para ver si se ajusta a tu rompecabezas de enfriamiento!

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *